- IP20
- Ambient temperature: -40 ° C ... 80 ° C
- Zones: 1.2
- 16 channels that can be used in pairs as input or output
- IC IIC intrinsic safety inputs / outputs with line fault monitoring and error indication and LED status for each channel
- Module in zone 1 replaceable on tension (Hot swap)
(à modifier dans le module "Réassurance")
(à modifier dans le module "Réassurance")
(à modifier dans le module "Réassurance")
The logical input / output module 9470/32 for zone 1 has 16 channels that can be used in pairs for ex i as input for contacts and initiators Namur (EN 60947-5-6) or as output for light lights and Low Power solenoid valves. 8 inputs can be used for frequencies up to 20 kHz, 4 for detecting direction of rotation.
| Ambiant temperature | -40 ° C to + 80 ° C |
|---|---|
| Temperature class | T4 |
| Warranty | 2¨ |
| Feed | 24V DC |
| Waterproofing protection (IP) | Ip20 |
| Application / usage | ATEX zone |
| ATEX zone | Zone 1/2 |
| Gas class | IIC |
| ATEX protection mode | Ex i (intrinsic safety) |
| Certificates | Atex.iecex |
| Material | Polyamide |
| Certificat_atex-en_us | DEKRA 12 ATEX0099 X |
| Certificat_iecex-en_us | IECEX DEK 12.0044X |
| Body colors | White |